T1 - Effects of hypophosphate concentrations on the characteristics of micro-arc oxidation coatings formed on biomedical NiTi alloy
AU - Xu, Jilin
AU - Luo, Junming
AU - Liu, Fu
PY - 2011
Y1 - 2011
N2 - Microarc oxidation coatings on biomedical NiTi alloy were prepared in aluminate electrolytes with and without hypophosphate addition. The effect of hypophosphate concentrations on the characteristics of micro-arc oxidation coatings has been studied. The compositions and surface morphologies of the coatings prepared in different hypophosphate concentrations were determined by energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and scanning electron microscopy (SEM). Surface roughness (Ra) and bonding strength of the coatings were measured by surface roughmeter and a direct pull-off test, respectively. The corrosion resistance of the coatings was evaluated in Hank's solution using potentiodynamic polarization tests. The results show that all of the coatings exhibit a typical porous surface structure and mainly consist of γ-Al2O3 crystal phase. With increasing the hypophosphate concentrations, the elemental contents of Ni, Ti and P increase while Al decreases; the pore sizes and surface roughness of the coatings decrease firstly, reaching a minimum value at 0.01mol/L, and then increase; at the same time, the bonding strength increases up to 60MPa, and then decreases. The corrosion resistance of the coatings decreases with the increase of the hypophosphate concentrations, but all of the coated samples is better than that of the uncoated NiTi alloy.
AB - Microarc oxidation coatings on biomedical NiTi alloy were prepared in aluminate electrolytes with and without hypophosphate addition. The effect of hypophosphate concentrations on the characteristics of micro-arc oxidation coatings has been studied. The compositions and surface morphologies of the coatings prepared in different hypophosphate concentrations were determined by energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and scanning electron microscopy (SEM). Surface roughness (Ra) and bonding strength of the coatings were measured by surface roughmeter and a direct pull-off test, respectively. The corrosion resistance of the coatings was evaluated in Hank's solution using potentiodynamic polarization tests. The results show that all of the coatings exhibit a typical porous surface structure and mainly consist of γ-Al2O3 crystal phase. With increasing the hypophosphate concentrations, the elemental contents of Ni, Ti and P increase while Al decreases; the pore sizes and surface roughness of the coatings decrease firstly, reaching a minimum value at 0.01mol/L, and then increase; at the same time, the bonding strength increases up to 60MPa, and then decreases. The corrosion resistance of the coatings decreases with the increase of the hypophosphate concentrations, but all of the coated samples is better than that of the uncoated NiTi alloy.
KW - Al O coating
KW - Biomedical NiTi alloy
KW - Corrosion resistance
KW - Hypophosphate
KW - Micro-arc oxidation
UR - https://www.scopus.com/pages/publications/80052992008
U2 - 10.4028/www.scientific.net/AMR.314-316.240
DO - 10.4028/www.scientific.net/AMR.314-316.240
M3 - 会议稿件
AN - SCOPUS:80052992008
SN - 9783037852156
T3 - Advanced Materials Research
SP - 240
EP - 244
BT - Advanced Manufacturing Technology
T2 - 2011 International Conference on Advanced Design and Manufacturing Engineering, ADME 2011
Y2 - 16 September 2011 through 18 September 2011
ER -