Skip to main navigation Skip to search Skip to main content

Effect of preionization in Aton-type Hall thruster on low frequency oscillation

  • Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

It was found through the experiments made with an Aton-type Hall thruster that some of the propellant was ionized in the buffer chamber by "quick electrons." This ionization is called "preionization" to discriminate it from the ionization in the discharge channel. The effect of preionization on low frequency oscillation was experimentally studied by changing the electric field intensity in the buffer chamber. The relationship between low frequency oscillation and preionization ratio was investigated through numerical simulation using a one-dimensional quasineutrality hydrodynamic model. The results obtained indicate that the amplitude of low frequency oscillation decreases as the preionization ratio increases. It was found through the analysis and numerical simulation of the physical process of low frequency oscillation that the positive feedback of electron density was the main cause of low frequency oscillation. The increase of preionization ratio decreases the amplitude of the feedback variation thereby reducing the amplitude of low frequency oscillation.

Original languageEnglish
Article number043502
JournalPhysics of Plasmas
Volume15
Issue number4
DOIs
StatePublished - 2008

Fingerprint

Dive into the research topics of 'Effect of preionization in Aton-type Hall thruster on low frequency oscillation'. Together they form a unique fingerprint.

Cite this