Skip to main navigation Skip to search Skip to main content

Device of capillary discharge with pre-pulse and main pulse to excite soft X-ray laser

  • Yong Peng Zhao*
  • , Yuan Li Cheng
  • , Qi Wang
  • , Da Wei Yang
  • *Corresponding author for this work
  • Harbin Institute of Technology
  • China National Nuclear Corporation

Research output: Contribution to journalArticlepeer-review

Abstract

Based on the introduction on circuit of main pulse and pre-pulse, the scheme about the trigger delay between pre-pulse and main pulse is introduced, and the experimental results about the adjustment of main pulse and pre-pulse are given. After the improvement on the device of capillary discharge soft X-ray laser, the original pre-pulse with over-high current is reduced and a new pre-pulse about tens of amperes is produced by pre-pulse generator. The adjusting results show that the current of pre-pulse is 20 A, and the first peak current of the main pulse is 40.1 kA with 26.6 ns rise-time and 38 ns duration. And the delay time between pre-pulse and main pulse is adjustable from 3 μs to 50 μs. These parameters can meet the need of soft X-ray laser generation.

Original languageEnglish
Pages (from-to)733-736
Number of pages4
JournalQiangjiguang Yu Lizishu/High Power Laser and Particle Beams
Volume16
Issue number6
StatePublished - Jun 2004

Keywords

  • Capillary discharge
  • Main pulse
  • Pre-pulse
  • Soft X-ray laser

Fingerprint

Dive into the research topics of 'Device of capillary discharge with pre-pulse and main pulse to excite soft X-ray laser'. Together they form a unique fingerprint.