Detailed gas/particle flow characteristics of an improved down-fired boiler with respect to a critical factor affecting coal burnout: Vent-air inclination angle

  • Qingxiang Wang
  • , Zhichao Chen*
  • , Hui Han
  • , Yaojie Tu
  • , Guangkui Liu
  • , Lingyan Zeng
  • , Zhengqi Li
  • *Corresponding author for this work
  • School of Energy Science and Engineering, Harbin Institute of Technology
  • Huazhong University of Science and Technology
  • China Special Equipment Inspection Institute

Research output: Contribution to journalArticlepeer-review

Abstract

The eccentric-swirl-secondary-air combustion technology has been confirmed to comprehensively solve high NOx emission and poor coal burnout for down-fired boilers with swirl burners. The influence of vent-air inclination angle (βv), a critical factor that affects coal burnout, on gas/particle flow characteristics is investigated to further decrease unburned combustible in fly ash. Gas/particle two-phase flow experiments under different βv (i.e., 10°, 20°, 28°, 40° and 50°) are performed by using a particle dynamic analyser in a 1:10-scale model of the full-scale improved boiler. With increasing βv, the under-arch recirculation zone and the recirculation velocities of gas/particle flows continuously increase. In the staged air region, the vertical velocities of gas/particle flows near water-cooled wall for βv of 40° and 50° are still as high as 2–4 m/s, however, the vertical velocities of gas/particle flows basically decay to negative values for smaller βv of 10° and 20°. At furnace section Y/Y0 from 0.220 to 0.369, the vertical fluctuation velocities of gas/particle flows near water-cooled wall for βv of 40° and 50° are significantly higher than those with βv of 10°, 20° and 28°, and the particle volume flux at the same horizontal position X/X0 constantly increases with increasing βv. Furthermore, the downward ejection ability of vent air to gas/particle flows from burners continuously improves, and the downward depth of gas/particle flows and the space utilization ratio of lower furnace both increase with increasing βv. The appropriate inclination angle of vent air for the improved boiler varies from 40° to 50°.

Original languageEnglish
Pages (from-to)570-584
Number of pages15
JournalEnergy
Volume182
DOIs
StatePublished - 1 Sep 2019
Externally publishedYes

Keywords

  • Down-fired boiler
  • Gas/particle flow characteristics
  • Novel combustion technology
  • PDA
  • Pulverized coal burnout
  • Vent-air inclination angle

Fingerprint

Dive into the research topics of 'Detailed gas/particle flow characteristics of an improved down-fired boiler with respect to a critical factor affecting coal burnout: Vent-air inclination angle'. Together they form a unique fingerprint.

Cite this