Abstract

In order to raise position accuracy and stability in wafer transmission process, a tactile sensing system which can measure both deviation of wafer to manipulator and friction acting on wafer simultaneously is introduced. Analysis on kinetic model abstracted from sensing system is made, and following algorithms are applied: micro displacement is calculated through pressure values acting on different sensing units, and meanwhile friction is calculated from relative velocity between permanent magnet and inductance. Through simulation, indicators of sensing unit are established. This sensing system has the capacity of detecting deviation ranging 0-5 mm with resolution 0.05 mm and measure friction ranging 0-0.64 N. The results indicate that this sensing system meets the requirements in orthocenter deviation and friction measurement in wafer transmission process.

Original languageEnglish
Title of host publicationKey Engineering Materials II
Pages1752-1756
Number of pages5
DOIs
StatePublished - 2012
Event2012 2nd International Conference on Key Engineering Materials, ICKEM 2012 - Singapore, Singapore
Duration: 26 Feb 201228 Feb 2012

Publication series

NameAdvanced Materials Research
Volume488-489
ISSN (Print)1022-6680

Conference

Conference2012 2nd International Conference on Key Engineering Materials, ICKEM 2012
Country/TerritorySingapore
CitySingapore
Period26/02/1228/02/12

Keywords

  • Friction measurement
  • Micro displacement measurements
  • Tactile sensor
  • Wafer transmission

Fingerprint

Dive into the research topics of 'Design of tactile sensor for measuring orthocenter deviation and friction in wafer transmission process'. Together they form a unique fingerprint.

Cite this