Abstract

Embedded sensor protection system (ESPS) for fibre optic sensor (FOS) has been presented in this paper. Protected Extrinsic Fabry-Perot interferometric (EFPI) sensors and Fibre Bragg Grating (FBG) have been used to monitor the cure progress and structural health status of concrete cylinders. The results indicate that the protected EFPI and FBG sensors are more sensitively to follow the change of environment temperature compared with commercial special strain gauges due to the special design of sensor protection system. The protected fibre optic sensors are suitable achieve the structural health monitoring in practical.

Original languageEnglish
Title of host publicationStructural Health Monitoring and Intelligent Infrastructure - Proceedings of the 2nd International Conference on Structural Health Monitoring of Intelligent Infrastructure, SHMII 2005
Pages461-464
Number of pages4
StatePublished - 2006
Event2nd International Conference on Structural Health Monitoring of Intelligent Infrastructure, SHMII 2005 - Shenzhen, China
Duration: 16 Nov 200518 Nov 2005

Publication series

NameStructural Health Monitoring and Intelligent Infrastructure - Proceedings of the 2nd International Conference on Structural Health Monitoring of Intelligent Infrastructure, SHMII 2005
Volume1

Conference

Conference2nd International Conference on Structural Health Monitoring of Intelligent Infrastructure, SHMII 2005
Country/TerritoryChina
CityShenzhen
Period16/11/0518/11/05

Fingerprint

Dive into the research topics of 'Cure monitor of concrete cylinder by using fibre optic sensors'. Together they form a unique fingerprint.

Cite this