Abstract

Systematic measurements have been carried out in agitated gas-liquid-solids systems to determine the just off-bottom suspension speed. A variety of solids sizes, solids concentrations, impeller sizes and tank sizes are used. The difference between the just off-bottom suspension speeds with and without gas sparging does not show a linear relationship with the gassing rate and the relation is system-dependent. The relative just off-bottom suspension speed RJSS = Njsg/Njs is found to be dependent only on the just suspension aeration number Najs = Qg/NjsD 3 and, for DT6 impellers, the relation is RJSS = 1 + mNa jsn with the values of 2.6 and 0.7 for m and n, respectively. The relation is independent of the impeller size, solids size, solids loading and tank size, and can be used to scale up laboratory data to full-scale mixing vessels. Data from different studies support the present findings.

Original languageEnglish
Pages (from-to)1-6
Number of pages6
JournalCanadian Journal of Chemical Engineering
Volume80
Issue number4
DOIs
StatePublished - Aug 2002
Externally publishedYes

Keywords

  • Just suspension speed
  • Solids suspension
  • Three-phase systems