@inproceedings{00b045482bc14140a746105bc26d9008,
title = "Correlation between load current mode and electrical contact resistance of a closed pair of contacts",
abstract = "The electrical contact resistance of closed contact pair is dependent on contact material physical characteristics, contact type (sphere-flat or flat-flat), contact surface status (clean or contaminated), but also contact current and mechanical load during measuring. The relationships between contact resistance and load current and load force with the use of DC mode and non-constant current mode measurement method are compared in this paper. The variations in thermoelectric voltage of contact pairs as a function of time with constant force load are presented.",
keywords = "Contact resistance, Delta mode, Load current, Measurement, Thermoelectric voltage",
author = "Chuwan Xiao and Teng Wang and Dazhao Yu and Ming Li and Sihuan Wang and Wanbin Ren",
note = "Publisher Copyright: {\textcopyright} 2019 by International Academic Publishers Ltd.; 7th International Conference on Reliability of Electrical Products and Electrical Contacts, ICREPEC 2019 ; Conference date: 04-11-2019 Through 06-11-2019",
year = "2019",
language = "英语",
series = "Proceedings of the 7th International Conference on Reliability of Electrical Products and Electrical Contacts, ICREPEC 2019",
publisher = "International Academic Publishers",
pages = "306--311",
editor = "Jingqin Wang and Jingying Zhao",
booktitle = "Proceedings of the 7th International Conference on Reliability of Electrical Products and Electrical Contacts, ICREPEC 2019",
}