Abstract
A terahertz (THz) in-line digital holography project has been proposed based on a CO2 pumped 2.52 THz continuous-wave laser and a pyroelectric-array camera used as the detector. The THz Gabor in-line digital holograms have been obtained and then the high resolution reconstruction of THz in-line digital holography was realized. The resolution of an in-line digital holography system has been tested by the use of a series of objects. High-quality and high-resolution reconstructed images have been obtained, and the real lateral resolution is higher than 0.2 mm. It can be inferred from the results that the THz Gabor in-line digital holography system has the abilities of real-time and high-resolution imaging.
| Original language | English |
|---|---|
| Pages (from-to) | 3228-3230 |
| Number of pages | 3 |
| Journal | Optics Letters |
| Volume | 37 |
| Issue number | 15 |
| DOIs | |
| State | Published - 1 Aug 2012 |
Fingerprint