Contact welding issues originating from the switching events extremely limit the lifespan and reliability of micro electromagnetic relays. In this paper, the contact welding failure phenomena of micro electromagnetic relays are recurred with the designed model switch. Meanwhile, the variations in contact voltage and contact resistance are recorded explicitly in the electrical endurance experiments, and the extracted contact break duration is used to characterize the contact welding phenomenon. Then, the contact welding failure mechanism is revealed with the help of the evolution of the eroded surface morphology and contact voltage. It is determined that the successive breaking behavior of parallel contact asperities is a threat of contact welding failure. By comparison, a novel designed rod contact with convex hull feature could inhibit the contact breaking delay phenomenon effectively.

Original languageEnglish
Pages (from-to)380-390
Number of pages11
JournalJournal of Failure Analysis and Prevention
Volume24
Issue number1
DOIs
StatePublished - Feb 2024
Externally publishedYes

Keywords

  • Contact break duration
  • Contact resistance
  • Contact welding
  • Electromagnetic relay
  • Molten metal bridge

Fingerprint

Dive into the research topics of 'Contact Welding Failure Analysis of Micro Electromagnetic Relays in Electrical Endurance Experiments'. Together they form a unique fingerprint.

Cite this