Abstract

A hot wind tunnel of annular cascade test rig is established for measuring temperature distribution on a real gas turbine blade surface with infrared camera. Besides, conjugate heat transfer numerical simulation is performed to obtain cooling efficiency distribution on both blade substrate surface and coating surface for comparison. The effect of thermal barrier coating on the overall cooling performance for blades is compared under varied mass flow rate of coolant, and spatial difference is also discussed. Results indicate that the cooling efficiency in the leading edge and trailing edge areas of the blade is the lowest. The cooling performance is not only influenced by the internal cooling structures layout inside the blade but also by the flow condition of the mainstream in the external cascade path. Thermal barrier effects of the coating vary at different regions of the blade surface, where higher internal cooling performance exists, more effective the thermal barrier will be, which means the thermal protection effect of coatings is remarkable in these regions. At the designed mass flow ratio condition, the cooling efficiency on the pressure side varies by 0.13 for the coating surface and substrate surface, while this value is 0.09 on the suction side.

Original languageEnglish
Pages (from-to)325-335
Number of pages11
JournalJournal of Thermal Science
Volume25
Issue number4
DOIs
StatePublished - 1 Aug 2016
Externally publishedYes

Keywords

  • conjugate heat transfer
  • cooling efficiency
  • gas turbine blade
  • thermal barrier coating

Fingerprint

Dive into the research topics of 'Conjugate heat transfer investigation on the cooling performance of air cooled turbine blade with thermal barrier coating'. Together they form a unique fingerprint.