Compressed air energy storage system with an ejector integrated in energy-release stage: Where is the optimal location of constant-pressure operation?

  • Shaowei Qing*
  • , Shangkun Ren
  • , Yan Wang
  • , Xiankui Wen
  • , Jingliang Zhong
  • , Shengli Tang
  • , E. Peng
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

As one of promising large-scale energy storage technologies, compressed air energy storage (CAES) system can release stable power by expanders in constant-pressure operation (CPO) mode. An ejector integrated in the valvetrain of energy-release stage has shown a certain potential for improving CAES system efficiency by recovering part of throttling loss. In such an ejector-integrated CAES system, different CPO locations may significantly influence total energy-release work by changing the inlet air flow rate of expanders. However, the issue of optimal CPO location for maximizing total energy-release work has been overlooked so far. Then, to demonstrate the optimal CPO location, the thermodynamic model of a 10 MW thermal-storage CAES system with or without the ejector is established, in which different low-pressure air sources (namely different suction positions of the ejector), motive air pressures, and CPO locations are considered, and the maximum entrainment ratio of the ejector is self-consistently calculated by a one-dimensional semi-empirical model. The results show that different CPO locations have negligible influence on the maximum entrainment ratio of the ejector, the optimal low-pressure air source, and the total amount of entrained low-pressure air, but change the total energy-release work, round-trip efficiency and profit significantly. For example, the total energy-release work, the rise amplitude of round-trip efficiency, and the profit of the ejector corresponding to the CPO location, namely the inlet of the second expander, can be respectively 4.72 × 109 J, 4.38% and 128$ bigger than those corresponding to the CPO location, namely the inlet of the first expander. As a result, the optimal CPO location is the inlet of the second expander. This paper provides a new optimal operating rule, namely the optimal CPO location, for the CAES system integrated with ejector technology.

Original languageEnglish
Article number124140
JournalApplied Energy
Volume375
DOIs
StatePublished - 1 Dec 2024

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Compressed air energy storage system
  • Constant-pressure operation location
  • Ejector
  • Performance analysis
  • Working parameters

Fingerprint

Dive into the research topics of 'Compressed air energy storage system with an ejector integrated in energy-release stage: Where is the optimal location of constant-pressure operation?'. Together they form a unique fingerprint.

Cite this