@inproceedings{e9b58a19b10a40d382aaa3a6579a9bc3,
title = "Compensation technique for the structural health monitoring system",
abstract = "The errors origin and mechanism of the sensor systems are proved in detail in this paper. The electric bridge circuit function method with the system zero bit removing, the system sensitivity lifting and the nonlinear error reducing is discussed and the systematic method and theory enhancement in the application of the half and entire bridge circuits of the differential and general disturbance compensation are proposed for the structural health monitoring sensor systems effectively in long term.",
author = "J. Teng and Liu, \{H. J.\}",
year = "2006",
language = "英语",
isbn = "0415396506",
series = "Structural Health Monitoring and Intelligent Infrastructure - Proceedings of the 2nd International Conference on Structural Health Monitoring of Intelligent Infrastructure, SHMII 2005",
pages = "585--590",
booktitle = "Structural Health Monitoring and Intelligent Infrastructure - Proceedings of the 2nd International Conference on Structural Health Monitoring of Intelligent Infrastructure, SHMII 2005",
note = "2nd International Conference on Structural Health Monitoring of Intelligent Infrastructure, SHMII 2005 ; Conference date: 16-11-2005 Through 18-11-2005",
}