Skip to main navigation Skip to search Skip to main content

Behavior of steel plate shear wall connected to frame beams only

  • Lanhui Guo*
  • , Qin Rong
  • , Xinbo Ma
  • , Sumei Zhang
  • *Corresponding author for this work
  • School of Civil Engineering, Harbin Institute of Technology
  • Center of Science and Technology of Construction Ministry of Housing and Urban-Rural Development

Research output: Contribution to journalArticlepeer-review

Abstract

This paper presents the study of steel plate shear walls which are connected to frame beams only. As the shear walls are connected to frame columns, the premature failure overall buckling or local buckling of frame columns can be prevented. In fact, most of both structural design engineers and architects prefer this kind of steel plate shear walls because the dimension of their opening space is relatively flexible by using several steel plates with small span-To-Height ratio placed parallel to each other. In this paper, two steel plate shear walls were fabricated and tested. The influence of stiffeners on the hysteretic behavior of this kind of member was studied. The experimental results showed that this kind of specimen had good ductility and energy dissipation capacity. The energy dissipation capacity of specimen with stiffeners was larger than that of the specimens without stiffeners. Meanwhile, the finite element method was applied to analyze the behavior of steel plate shear walls, whose results were validated by comparing with the corresponding experimental results. Analytical results showed that the free edges deformed with evident out-Of-Plane deformation and should be constrained by stiffeners to meet the design requirements. The energy dissipation capacity is much better for steel plate shear walls with lower height-To-Thickness ratio and larger span-Toheight ratio. At last, the skeleton curve of steel plate shear wall was proposed for calculating the elastic rigidity and loadcarrying capacity.

Original languageEnglish
Pages (from-to)467-479
Number of pages13
JournalInternational Journal of Steel Structures
Volume11
Issue number4
DOIs
StatePublished - Dec 2011
Externally publishedYes

Keywords

  • Connected to frame beams
  • Ductility
  • Height-To-Thickness ratio
  • Span-To-Height ratio
  • Steel plate shear wall (SPSW)

Fingerprint

Dive into the research topics of 'Behavior of steel plate shear wall connected to frame beams only'. Together they form a unique fingerprint.

Cite this