Skip to main navigation Skip to search Skip to main content

Application of ZIF-8 nanocomposite membrane in microbial desalination cells for simultaneous heavy metal removal and biofouling prevention

  • Nicholas Miwornunyuie*
  • , Huang Jingyu*
  • , Lei Chen
  • , Li Ke
  • , Desmond Ato Koomson
  • , David Ewusi-Mensah
  • , Prince Atta Opoku
  • *Corresponding author for this work
  • Hohai University
  • Tianjin University
  • Jilin Jianzhu University

Research output: Contribution to journalArticlepeer-review

Abstract

Microbial desalination cells (MDC) syndicate the advantage of physical separation by using membranes to create conditions required for Bioelectrochemical processes for the treatment of various domestic and industrial wastewater, while simultaneously desalinating saline water and generating bioenergy. However, since the introduction of this technology, heavy metal removal has been a challenge, and membrane fouling has become a major bottleneck limiting the optimum performance and efficiency of this technology. This study incorporated the use of ZIF-8 nanocomposite membrane via phase inversion mechanism in MDC for simultaneous heavy metal removal and membrane biofouling prevention. The study was conducted in two MDC systems; MDC-Control (without the ZIF-8 nanocomposite membrane) and MDC with ZIF-8 nanocomposite membrane. The results from the experiment shown that maximum removal efficiency of 85.7%, 84.3%, 84.0%, and 90.61% was obtained for Cu2+, Zn2+, Pb2+, and Cd2+ respectively in MDC-ZIF-8, while MDC control showed 54.17%, 59.71%, 51.94%, and 54.17%. The results were well fitted to the Langmuir adsorption isotherm with correlation coefficients (R2) > 0.99 in all cases for MDC-ZIF-8. A maximum adsorption capacity (Qmax) of 292 mg g−1 was attained for all four metal ions in MDC-ZIF-8. Besides, after 38 days of continuous operation with two complete desalination for both systems, the SEM-EDS characterization analysis, polarization characteristics, and power generation revealed antifouling characteristics of ZIF-8 nanocomposite membrane incorporated in MDC. The integration of the ZIF-8 nanocomposite membrane proved to be simultaneously efficient in biofouling prevention and heavy metal removal without jeopardizing the system's ability for wastewater treatment, bioelectricity generation, and desalination processes.

Original languageEnglish
Article number135386
JournalChemosphere
Volume306
DOIs
StatePublished - Nov 2022
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Biofouling
  • Heavy metals
  • Microbial desalination cells
  • Zeolitic imidazolate framework-8

Fingerprint

Dive into the research topics of 'Application of ZIF-8 nanocomposite membrane in microbial desalination cells for simultaneous heavy metal removal and biofouling prevention'. Together they form a unique fingerprint.

Cite this