Skip to main navigation Skip to search Skip to main content

Application of system identification in a practical active noise control system

  • Yu Yuan
  • , Zhaoyang Sun
  • , Hongwei Zhang*
  • *Corresponding author for this work
  • Xihua University
  • Southwest Jiaotong University
  • Harbin Institute of Technology Shenzhen

Research output: Contribution to journalArticlepeer-review

Abstract

Noise pollution has become increasingly severe around the world due to fast urbanization. How to soundproof windows from outside noise is of significant interest for both academia and industry. This paper reports an experimental implementation of normalized minmax active noise control (ANC) algorithm on an open window system, where identifying the model of acoustic sound paths plays a central role. By doing this, traffic noise is attenuated by the ANC system, leading to a relatively quiet indoor environment, while the natural lighting and ventilation functions of a window are remained. Our experiments show that an average of 19 dB(A) noise reduction is achieved.

Original languageEnglish
Pages (from-to)282-291
Number of pages10
JournalControl Theory and Technology
Volume22
Issue number2
DOIs
StatePublished - May 2024
Externally publishedYes

Keywords

  • Active noise control
  • Multi-input–multi-output system
  • Normalized minimax algorithm
  • System identification

Fingerprint

Dive into the research topics of 'Application of system identification in a practical active noise control system'. Together they form a unique fingerprint.

Cite this