Abstract
Based on a mechanical seal which is already used in reactor coolant pumps (RCP), an interference fit simulation model is established by ANSYS. End face deformation of the stator/rotor seal ring is calculated. As a result, the mechanical seal's leakage is available, which is close to the specific operation value. The comparison results between leakages which are calculated by model include interference fit or not illustrated that interference fit has significant influence on structural analysis and should be paid more attention on it. Using this example, the idea and method of ANSYS interference fit analysis is demonstrated.
| Original language | English |
|---|---|
| Pages (from-to) | 153-159 |
| Number of pages | 7 |
| Journal | Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering |
| Volume | 53 |
| Issue number | 5 |
| DOIs | |
| State | Published - 5 Mar 2017 |
| Externally published | Yes |
Keywords
- ANSYS
- Contact analysis
- Interference fit
- Mechanical seals
Fingerprint
Dive into the research topics of 'ANSYS Interference Fit Analysis of Mechanical Seals in Reactor Coolant Pumps'. Together they form a unique fingerprint.Cite this