Skip to main navigation Skip to search Skip to main content

Analysis to fluid pressure in spatial domain in hydro-mechanical deep drawing

Research output: Contribution to journalArticlepeer-review

Abstract

Fluid pressure in spatial domain was solved by means of finite element method, and the distribution of fluid pressure was analyzed for different gaps in the straight-wall and the flange in hydro-mechanical deep drawing(HDD). Based on the distribution of fluid pressure in the flange, the minimum blank holding force was given in HDD. A method to select the gap and determine the minimum blank holding force was presented. The condition of the uniform pressure below the die corner was discussed. The results indicate that the gap ratio between the straight-wall and the flange determines the distribution of fluid pressure. Larger the gap ratio will result in more homogeneous distribution of fluid pressure in the straight-wall and the die corner.

Original languageEnglish
Pages (from-to)755-758
Number of pages4
JournalHarbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology
Volume42
Issue number5
StatePublished - May 2010
Externally publishedYes

Keywords

  • Blank holding force
  • Fluid pressure
  • Gap
  • Hydro-mechanical deep drawing

Fingerprint

Dive into the research topics of 'Analysis to fluid pressure in spatial domain in hydro-mechanical deep drawing'. Together they form a unique fingerprint.