Abstract
The arc electrical signals were collected the data acquisition system in the plasma-MIG welding process, and the U-Ul-UU-I diagrams analyzed with the Labview software were obtained. The difference of arc characteristic between plasma-MIG arc and MIG arc was studied and the effect of increase of MIG current on the electric signals of the Plasma-MIG arc was analyzed. The unstable arc electrical signals of Plasma-MIG were gathered and the result indicates that some contacts exist between inner arc and outer arc.
| Original language | English |
|---|---|
| Pages (from-to) | 59-62 |
| Number of pages | 4 |
| Journal | Hanjie Xuebao/Transactions of the China Welding Institution |
| Volume | 27 |
| Issue number | 8 |
| State | Published - Aug 2006 |
Keywords
- Arc signal
- LabVIEW
- MIG
- Plasma-MIG
Fingerprint
Dive into the research topics of 'Analysis of plasma-MIG arc signal based on LabVIEW'. Together they form a unique fingerprint.Cite this