Skip to main navigation Skip to search Skip to main content

Analysis and fault-tolerant control of inter-turn short-circuit fault for five-phase permanent-magnet synchronous machine

  • Zaiping Zheng
  • , Qiqi Li
  • , Xuyang Li
  • , Ping Zheng*
  • , Kaichun Wang
  • , Peijuan Cui
  • *Corresponding author for this work
  • School of Electrical Engineering and Automation, Harbin Institute of Technology
  • Beijing Institute of Precision Mechatronics and Controls
  • Laboratory of Aerospace Servo Actuation and Transmission

Research output: Contribution to journalArticlepeer-review

Abstract

For the demand of high reliability in the aerospace field, multi-phase electric machines have become a research hotspot for the fault-tolerant ability. Inter-turn short-circuit fault is one of the main fault forms in the electric machine. The fault mechanism, diagnosis method and fault-tolerant control strategy of inter-turn short-circuit fault of the open-winding five-phase permanent-magnet synchronous machine that is used as the starter/generator system are studied in this paper. Firstly, the fault mechanism of the inter-turn short-circuit fault (ITSCF) is analyzed. The characteristics of phase voltage, inter-turn short-circuit current and torque ripple are compared using the phase winding open-circuit method and the phase winding short-circuit method. Secondly, a fault diagnosis method based on the information fusion is proposed, which determines the fault phase firstly and then identifies the inter-turn short-circuit ratio. According to the fault mechanism, a fault-tolerant control method is proposed, in which the accurate inter-turn short-circuit ratio and inter-turn short-circuit current are not required. The proposed fault-tolerant control method has similar torque ripple compared with the control method using accurate inter-turn short-circuit ratio and inter-turn short-circuit current. Finally, the effectiveness of the proposed fault-tolerant control method has been verified by experimental results.

Original languageEnglish
Pages (from-to)7360-7373
Number of pages14
JournalEnergy Reports
Volume8
DOIs
StatePublished - Nov 2022
Externally publishedYes

Keywords

  • Fault mechanism
  • Fault-tolerant control
  • Five-phase permanent-magnet synchronous machine
  • Inter-turn short-circuit fault
  • Open-winding

Fingerprint

Dive into the research topics of 'Analysis and fault-tolerant control of inter-turn short-circuit fault for five-phase permanent-magnet synchronous machine'. Together they form a unique fingerprint.

Cite this