Skip to main navigation Skip to search Skip to main content

An in-pipe micro robot actuated by piezoelectric bimorphs

  • Pinkuan Liu*
  • , Zhijie Wen
  • , Lining Sun
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

A novel in-pipe micro robot providing stable and accurate locomotion inside a tubular structure with diameters ranging from 16 mm to 18 mm is presented in this paper. Driven by impulsive voltages, deflections of the piezoelectric bimorphs are generated and then converted into translational locomotion by the principle of the Impact Drive Mechanism (IDM). Theoretical analysis of the proposed system is performed based on a simplified mechanical model. Then dynamic simulations of the dynamic behavior are performed. Finally, an experiment is conducted to investigate the moving ability of this device. The results demonstrate that a maximum translational velocity of 3.5 mm/s can be obtained under an impulsive driving voltage with peak value at 50 V and frequency of 1100 Hz. Both theoretical analysis and experimental trials prove that the principle of IDM actuated by piezoelectric bimorphs is feasible and robust for achieving accurate locomotion of the micro robot in pipes with diameters of less than 20 mm.

Original languageEnglish
Pages (from-to)2134-2142
Number of pages9
JournalChinese Science Bulletin
Volume54
Issue number12
DOIs
StatePublished - Jun 2009

Keywords

  • Impact drive mechanism (IDM)
  • In-pipe micro robot
  • Piezoelectric bimorph

Fingerprint

Dive into the research topics of 'An in-pipe micro robot actuated by piezoelectric bimorphs'. Together they form a unique fingerprint.

Cite this