Skip to main navigation Skip to search Skip to main content

A Study on Indoor Air Quality of Urban Residential Buildings in China

  • Hiroshi Yoshino*
  • , Junhong Zhao
  • , Yasuko Yoshino
  • , Kazukiyo Kumagai
  • , Yueyong Ni
  • , Zhenhai Li
  • , Jing Liu
  • , Takayuki Shigeno
  • , Hiroyuki Miyasaka
  • , Yukio Yanagisawa
  • *Corresponding author for this work
  • Tohoku University
  • Nihon University
  • The University of Tokyo
  • Tongji University
  • Toshiba Corporation

Research output: Contribution to journalArticlepeer-review

Abstract

The purpose of this survey was to examine the actual conditions of residential indoor air quality in urban areas in China. In this survey, the concentrations of about 16 volatile organic compounds (VOCs) and two carbonyl compounds were measured at 75 apartments in seven Chinese cities, viz., Urumqi, Harbin, Beijing, Shanghai, Changsha, Chongqing, and Kunming. In this paper, the measurement results for six VOCs and two carbonyl compound concentrations are summarized. It was found that the average concentrations of benzene, toluene, and formaldehyde were relatively high.

Original languageEnglish
Pages (from-to)495-500
Number of pages6
JournalJournal of Asian Architecture and Building Engineering
Volume4
Issue number2
DOIs
StatePublished - 2005

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 11 - Sustainable Cities and Communities
    SDG 11 Sustainable Cities and Communities

Keywords

  • China
  • Field measurement
  • Indoor air quality
  • Urban residential building

Fingerprint

Dive into the research topics of 'A Study on Indoor Air Quality of Urban Residential Buildings in China'. Together they form a unique fingerprint.

Cite this