Abstract
The purpose of this survey was to examine the actual conditions of residential indoor air quality in urban areas in China. In this survey, the concentrations of about 16 volatile organic compounds (VOCs) and two carbonyl compounds were measured at 75 apartments in seven Chinese cities, viz., Urumqi, Harbin, Beijing, Shanghai, Changsha, Chongqing, and Kunming. In this paper, the measurement results for six VOCs and two carbonyl compound concentrations are summarized. It was found that the average concentrations of benzene, toluene, and formaldehyde were relatively high.
| Original language | English |
|---|---|
| Pages (from-to) | 495-500 |
| Number of pages | 6 |
| Journal | Journal of Asian Architecture and Building Engineering |
| Volume | 4 |
| Issue number | 2 |
| DOIs | |
| State | Published - 2005 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 11 Sustainable Cities and Communities
Keywords
- China
- Field measurement
- Indoor air quality
- Urban residential building
Fingerprint