Skip to main navigation Skip to search Skip to main content

A separated calibration method for inertial measurement units mounted on three-axis turntables

  • Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

Inertial Measurement Unit (IMU) calibration accuracy is easily affected by turntable errors, so the primary aim of this study is to reduce the dependence on the turntable’s precision during the calibration process. Firstly, the indicated-output of the IMU considering turntable errors is constructed and with the introduction of turntable errors, the functional relationship between turntable errors and the indicated-output was derived. Then, based on a D-suboptimal design, a calibration method for simultaneously identifying the IMU error model parameters and the turntable errors was proposed. Simulation results showed that some turntable errors could thus be effectively calibrated and automatically compensated. Finally, the theoretical validity was verified through experiments. Compared with the traditional method, the method proposed in this paper can significantly reduce the influence of the turntable errors on the IMU calibration accuracy.

Original languageEnglish
Article number2846
JournalSensors
Volume18
Issue number9
DOIs
StatePublished - Sep 2018

Keywords

  • Calibration method
  • Error modeling
  • IMU
  • Parameter estimation
  • Separated calibration

Fingerprint

Dive into the research topics of 'A separated calibration method for inertial measurement units mounted on three-axis turntables'. Together they form a unique fingerprint.

Cite this