TY - GEN
T1 - A novel shunt hybrid power filter for suppressing harmonics
AU - He, Na
AU - Wu, Jian
AU - Xu, Dianguo
PY - 2006
Y1 - 2006
N2 - Shunt hybrid power filter has been proved to be a useful approach to eliminate current harmonics caused by nonlinear loads. The passive power filter suppresses harmonic currents produced by the load, whereas the active power filter improves filtering characteristics of the passive filter. Nowadays, the passive filter has many kinds of topologies. Among them, the single tuned passive filter has gained extensive interests because of its simplicity and practicability. Different from conventional design methods, a novel design method for the single tuned passive filter is proposed in this paper to minimize the rating of active power filter. The filtering characteristics of hybrid power filter are detailed in frequency domain. Furthermore, in order to make the new topology designed in this paper work well, a novel compound controller is proposed which assures good filtering characteristics, high system stability and small active power filter rating. The stability of the compound controller is analyzed in time and frequency domain. The simulation and experimental results verify the validity and effectiveness of the system.
AB - Shunt hybrid power filter has been proved to be a useful approach to eliminate current harmonics caused by nonlinear loads. The passive power filter suppresses harmonic currents produced by the load, whereas the active power filter improves filtering characteristics of the passive filter. Nowadays, the passive filter has many kinds of topologies. Among them, the single tuned passive filter has gained extensive interests because of its simplicity and practicability. Different from conventional design methods, a novel design method for the single tuned passive filter is proposed in this paper to minimize the rating of active power filter. The filtering characteristics of hybrid power filter are detailed in frequency domain. Furthermore, in order to make the new topology designed in this paper work well, a novel compound controller is proposed which assures good filtering characteristics, high system stability and small active power filter rating. The stability of the compound controller is analyzed in time and frequency domain. The simulation and experimental results verify the validity and effectiveness of the system.
KW - Active power filter (APF)
KW - Harmonics
KW - Passive power filter (PPF)
KW - Shunt hybrid power filter (SHPF)
UR - https://www.scopus.com/pages/publications/53749100988
U2 - 10.1109/ISIE.2006.295800
DO - 10.1109/ISIE.2006.295800
M3 - 会议稿件
AN - SCOPUS:53749100988
SN - 1424404975
SN - 9781424404971
T3 - IEEE International Symposium on Industrial Electronics
SP - 1155
EP - 1160
BT - International Symposium on Industrial Electronics 2006, ISIE 2006
T2 - International Symposium on Industrial Electronics 2006, ISIE 2006
Y2 - 9 July 2006 through 13 July 2006
ER -