Skip to main navigation Skip to search Skip to main content

A novel degree of observability used for measurement selections in gas path diagnostics

  • Xingxing Pu*
  • , Shangming Liu
  • , Hongde Jiang
  • , Daren Yu
  • *Corresponding author for this work
  • Tsinghua University
  • School of Energy Science and Engineering, Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

A novel method for measurement selections of gas path diagnostics has been developed. This method is based on the singular value decomposition of the observability matrix of linear systems, which are a good approximation of the nonlinear ones for small deviations. It also employs the concept of the degree of observability to formulate the criteria. The states with high degree of observability and the measurement sets with high overall degree of observability result in high estimation accuracy in gas path diagnostics. A heavy-duty gas turbine model is used to validate this method. The influence of the gas turbine nonlinearity, the measurement noise, and the overdetermined measurement on degree of observability is analyzed. The overall degree of observability is calculated for different measurement sets of heavy-duty gas turbine. The gas path diagnostics simulations with different measurement sets using the weighted least-squares estimation method and the extended Kalman filter are conducted. The quality of gas path diagnostics simulation with different measurement sets is assessed and the results demonstrate the capability of the developed method for measurement selections in gas path diagnostics.

Original languageEnglish
Article number081601
JournalJournal of Engineering for Gas Turbines and Power
Volume134
Issue number8
DOIs
StatePublished - 2012
Externally publishedYes

Keywords

  • degree of observability
  • gas path diagnostics
  • gas turbine
  • measurement selections
  • singular value decomposition

Fingerprint

Dive into the research topics of 'A novel degree of observability used for measurement selections in gas path diagnostics'. Together they form a unique fingerprint.

Cite this