Abstract
Hydrogen peroxide interference on chemical oxygen demand (COD) measurement has been a big problem in the application of the Fenton process. However, there is no simple and effective method available to address this problem, although several methods have been reported in the literature. In this study, a new method has been developed based on Na2SO3reduction and O2oxidation, which has easy operation and short time requirement. Na2SO3reduction was used to remove H2O 2in water samples, which was independent of pH in the investigated range of 2.50-11.95. Residual Na2SO3was removed by subsequent O2oxidation, and effects of initial solution pH, ferric ion dosage, and stirring speed were explored. Solution pH below 3.0 and stirring speed of 700 rev min-1 could ensure a sufficiently high oxidation rate for Na2SO3with ferric ion higher than 0.469 mM. This new method was proven to be effective in the matrix of Fenton treating real landfill leachate. Meanwhile, the procedure for this method in other applications was proposed in detail. To the best of our knowledge, this newly developed method is the most simple and effective way to avoid H 2O2interference on COD analysis.
| Original language | English |
|---|---|
| Pages (from-to) | 1529-1535 |
| Number of pages | 7 |
| Journal | Water Science and Technology |
| Volume | 68 |
| Issue number | 7 |
| DOIs | |
| State | Published - 2013 |
Keywords
- Chemical oxygen demand
- Fenton reaction
- Hydrogen peroxide interference
- NaSOreduction
- O oxidation
Fingerprint
Dive into the research topics of 'A novel and quick method to avoid H2O2interference on COD measurement in Fenton system by Na2SO3reduction and O2 oxidation'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver