Skip to main navigation Skip to search Skip to main content

A Multi-Level Operation Method for Improving the Resilience of Power Systems under Extreme Weather through Preventive Control and a Virtual Oscillator

  • Chenghao Li
  • , Di Zhang
  • , Ji Han*
  • , Chunsun Tian
  • , Longjie Xie
  • , Chenxia Wang
  • , Zhou Fang
  • , Li Li
  • , Guanyu Zhang
  • *Corresponding author for this work
  • State Grid Corporation of China
  • School of New Energy, Harbin Institute of Technology Weihai
  • Harbin Institute of Technology at Weihai
  • School of Electrical Engineering and Automation, Harbin Institute of Technology

Research output: Contribution to journalArticlepeer-review

Abstract

This paper proposes a multi-level operation method designed to enhance the resilience of power systems under extreme weather conditions by utilizing preventive control and virtual oscillator (VO) technology. Firstly, a novel model for predicting time intervals between successive failures of the power system during extreme weather is introduced. Based on this, this paper proposes a preventive control method considering the system ramping and transmission constraints prior to failures so as to ensure the normal electricity demand within the system. Further, a VO-based adaptive frequency control strategy is designed to accelerate the regulation speed and eliminate the frequency deviation. Finally, the control performance is comprehensively compared under different experimental conditions. The results verify that the method accurately predicted the time of the line fault occurrence, with a maximum error not exceeding 3 min compared to the actual occurrence; also, the virtual oscillator control (VOC) strategy outperformed traditional droop control in frequency stabilization, achieving stability within 2 s compared to the droop control’s continued fluctuations beyond 20 s. These results highlight VOC’s superior effectiveness in frequency stability and control in power systems.

Original languageEnglish
Article number1812
JournalSensors
Volume24
Issue number6
DOIs
StatePublished - Mar 2024
Externally publishedYes

Keywords

  • extreme weather
  • multi-level operation
  • preventive control
  • resilience of power system
  • virtual oscillator

Fingerprint

Dive into the research topics of 'A Multi-Level Operation Method for Improving the Resilience of Power Systems under Extreme Weather through Preventive Control and a Virtual Oscillator'. Together they form a unique fingerprint.

Cite this