Skip to main navigation Skip to search Skip to main content

A Hybrid Hand-Eye Calibration Method for Multilink Cable-Driven Hyper-Redundant Manipulators

  • Jianqing Peng
  • , Wenfu Xu
  • , Fengxu Wang
  • , Yu Han*
  • , Bin Liang*
  • *Corresponding author for this work
  • Sun Yat-Sen University
  • Guangdong Provincial Key Laboratory of Fire Science and Intelligent Emergency Technology
  • Harbin Institute of Technology Shenzhen
  • Tsinghua University

Research output: Contribution to journalArticlepeer-review

Abstract

Multilink cable-driven hyper-redundant manipulators (MCDHMs) have a slender body and flexible movement characteristics, which are very suitable for complex unstructured environments. Since MCDHMs have multiple coupling between active cables, linkage cables, joints, and the end-effector, the mathematical modeling of the segmented linkage MCDHM becomes more complicated, and the uncertainty of its model makes the motion accuracy of the end-effector become low. Traditional calibration methods that rely solely on eye-in-hand or eye-to-hand calibration method to calibrate the MCDHM model will produce relatively large errors. This article proposes a hybrid hand-eye calibration method, which eliminates the errors introduced by inaccurate kinematics models through the fusion modeling of eye-in-hand and eye-to-hand. First, for unstructured application scenarios, the hybrid calibration framework under the condition of large model errors is introduced, and then the multiple kinematics model of the MCDHM is derived. Then, two different types of hybrid hand-eye calibration equations are derived and solved by the recursive iteration method. Furthermore, according to the hand-eye calibration result, the MCDHM kinematic parameters are calibrated by the particle swarm optimization (PSO) method. Finally, in order to demonstrate the feasibility and superiority of the hybrid calibration method, experiments are carried out on the real MCDHM to further verify the proposed method. The experimental results show that the proposed hybrid calibration method has higher calibration accuracy.

Original languageEnglish
Article number9427165
JournalIEEE Transactions on Instrumentation and Measurement
Volume70
DOIs
StatePublished - 2021
Externally publishedYes

Keywords

  • Experiment
  • eye-hand calibration
  • hyper-redundant manipulator
  • particle swarm optimization (PSO)
  • segmented linkage

Fingerprint

Dive into the research topics of 'A Hybrid Hand-Eye Calibration Method for Multilink Cable-Driven Hyper-Redundant Manipulators'. Together they form a unique fingerprint.

Cite this