TY - GEN
T1 - A fast medical image registration method based on nonlinear correlation measurement
AU - Jin, Jing
AU - Wang, Qiang
AU - Shen, Yi
PY - 2005
Y1 - 2005
N2 - In this paper a new approach to the problem of rigid body registration is proposed, using a concept of nonlinear correlation information entropy (NCIE) as the new matching criterion. The presented method applies NCIE to measure the correlation degree between the image intensities of corresponding voxel in both images. Registration is achieved by adjustment of the relative position until the NCIE between the images is maximized. However, unlike the mutual information, NCIE changes in the closed interval [0, 1], and around the extremum it varies sharply, which makes it possible that a threshold of NCIE can be used to boost the search the registration transformation. Using this feature of NCIE, we registered a rotated floating image with a reference image combined the variant step-size searching for further enhancing the searching speed. Our results demonstrate the proposed method can take care the differences in contrast between the floating and reference images. Meanwhile, as the mutual information, NCIE criterion can be achieved automatically and without any preprocessing.
AB - In this paper a new approach to the problem of rigid body registration is proposed, using a concept of nonlinear correlation information entropy (NCIE) as the new matching criterion. The presented method applies NCIE to measure the correlation degree between the image intensities of corresponding voxel in both images. Registration is achieved by adjustment of the relative position until the NCIE between the images is maximized. However, unlike the mutual information, NCIE changes in the closed interval [0, 1], and around the extremum it varies sharply, which makes it possible that a threshold of NCIE can be used to boost the search the registration transformation. Using this feature of NCIE, we registered a rotated floating image with a reference image combined the variant step-size searching for further enhancing the searching speed. Our results demonstrate the proposed method can take care the differences in contrast between the floating and reference images. Meanwhile, as the mutual information, NCIE criterion can be achieved automatically and without any preprocessing.
KW - Image registration
KW - Medical image processing
KW - Nonlinear correlation information entropy
UR - https://www.scopus.com/pages/publications/33847102629
U2 - 10.1109/IMTC.2004.1351335
DO - 10.1109/IMTC.2004.1351335
M3 - 会议稿件
AN - SCOPUS:33847102629
SN - 078038248X
SN - 0780388798
SN - 9780780388796
T3 - Conference Record - IEEE Instrumentation and Measurement Technology Conference
SP - 1429
EP - 1432
BT - IMTC'05 - Proceedings of the IEEE Instrumentation and Measurement Technology Conference
T2 - IMTC'05 - Proceedings of the IEEE Instrumentation and Measurement Technology Conference
Y2 - 16 May 2005 through 19 May 2005
ER -