@inproceedings{2e77cdfb49a140ffbc6610ce697820ba,
title = "A downhole multi-parameter monitoring system for electrical submersible pump",
abstract = "In order to achieve online monitoring the downhole information related to ESP working state, an ESP downhole parameters monitoring system based on current loop data transmission method was developed. Compared with other methods, the current loop data transmission method was relatively insensitive to interference in harsh environment. By means of ESP motor's winding and symmetrical reactance located on the ground, the loop for current transmission could be built. The principle of current loop transmission and involved circuit were introduced. An experiment simulating the hostile downhole environment was conducted to test the transmission effect, by which the reliability and accuracy of current loop data transmission was demonstrated.",
keywords = "Current loop, Downhole parameter, ESP, Monitoring",
author = "Miaoxin Jin and Pengmiao Zhang and Gang Li and Qiang Gao and Xiaolu Li and DIanguo Xu",
note = "Publisher Copyright: {\textcopyright} 2015 Korean Institute of Power Electronics.; 9th International Conference on Power Electronics - ECCE Asia, ICPE 2015-ECCE Asia ; Conference date: 01-06-2015 Through 05-06-2015",
year = "2015",
month = jul,
day = "27",
doi = "10.1109/ICPE.2015.7168111",
language = "英语",
series = "9th International Conference on Power Electronics - ECCE Asia: {"}Green World with Power Electronics{"}, ICPE 2015-ECCE Asia",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "2427--2431",
booktitle = "9th International Conference on Power Electronics - ECCE Asia",
address = "美国",
}