TY - GEN
T1 - A comparison of three types of pulse signals
T2 - 6th International Conference on Biomedical Engineering and Informatics, BMEI 2013
AU - Wang, Peng
AU - Zhang, Hongzhi
AU - Zuo, Wangmeng
AU - Zhang, David
AU - Wu, Qiufeng
PY - 2013
Y1 - 2013
N2 - Pulse diagnosis has been extensively applied in China and Ayuredic for thousands of years. Recently more and more research interests have been given on computerized pulse diagnosis where sensor techniques are used to acquire the pulse signal and machine learning techniques are adopted to analyze the health condition based on the acquired pulse signals. By far, a number of sensors had been employed for pulse signal acquisition, which can be grouped into three categories, i.e., the pressure sensor, the photoelectric sensor, and the ultrasound sensor. To guide the sensor selection for computational pulse diagnosis, in this paper we analyze the physical meanings and sensitivities of signals sampled by these three types of sensors. The complementary information of different sensors is discussed from both cardiovascular fluid dynamics and comparative experiments by evaluating the disease classification performance. Signals acquired using different sensors are sensitive to different physiological and pathological factors. By combining signals from different sensor, improved diagnosis performance can be obtained.
AB - Pulse diagnosis has been extensively applied in China and Ayuredic for thousands of years. Recently more and more research interests have been given on computerized pulse diagnosis where sensor techniques are used to acquire the pulse signal and machine learning techniques are adopted to analyze the health condition based on the acquired pulse signals. By far, a number of sensors had been employed for pulse signal acquisition, which can be grouped into three categories, i.e., the pressure sensor, the photoelectric sensor, and the ultrasound sensor. To guide the sensor selection for computational pulse diagnosis, in this paper we analyze the physical meanings and sensitivities of signals sampled by these three types of sensors. The complementary information of different sensors is discussed from both cardiovascular fluid dynamics and comparative experiments by evaluating the disease classification performance. Signals acquired using different sensors are sensitive to different physiological and pathological factors. By combining signals from different sensor, improved diagnosis performance can be obtained.
KW - computerized pulse diagnosis
KW - photoelectric sensor
KW - pressure sensor
KW - pulse signal acquisition
KW - ultrasound sensor
UR - https://www.scopus.com/pages/publications/84896304351
U2 - 10.1109/BMEI.2013.6746962
DO - 10.1109/BMEI.2013.6746962
M3 - 会议稿件
AN - SCOPUS:84896304351
SN - 9781479927616
T3 - Proceedings of the 2013 6th International Conference on Biomedical Engineering and Informatics, BMEI 2013
SP - 352
EP - 357
BT - Proceedings of the 2013 6th International Conference on Biomedical Engineering and Informatics, BMEI 2013
PB - IEEE Computer Society
Y2 - 16 December 2013 through 18 December 2013
ER -