Skip to main navigation Skip to search Skip to main content

钢 / 聚丙烯混杂纤维增强超高性能混凝土梁受弯性能试验

Translated title of the contribution: Experimental Study on Flexural Performance of Steel/Polypropylene Hybrid Fiber-Reinforced Ultra-High Performance Concrete Beams
  • Jia Tan
  • , Chengjun Zhao
  • , Hai Guo
  • , Weidong Wang
  • , Jiangfeng Lin
  • , Xiangguo Wu*
  • , Chenglu Zou
  • *Corresponding author for this work
  • Ltd.
  • China Construction Infrastructure Co., Ltd.
  • China Construction First Group Corporation Limited
  • Fuzhou University
  • Ltd.

Research output: Contribution to journalArticlepeer-review

Abstract

Steel/polypropylene (PP) hybrid fibers can enhance the high-temperature resistance and corrosion durability of ultra-high performance concrete (UHPC) structures, but simultaneously affect their structural mechanical performance. To investigate the influence of reinforcement ratio on the flexural behavior of steel/PP hybrid fiber-reinforced UHPC beams and quantify the improvement in mechanical properties, the authors design a series of such beams with different reinforcement ratios (0.28% to 1.27%) for flexural tests, comparing them with normal C50 reinforced concrete beams of identical cross-section. Key performance indicators including load-displacement curves, crack development patterns, load-steel strain curves, strain profile at mid-span, and ultimate load-carrying capacity are observed. The results indicate that: (1) Under the same cross-sectional conditions, compared to C50 concrete beams, the steel/PP hybrid fiber-reinforced UHPC beams exhibit increases of 6.67%, 16.00%, 25.00%, and 36.30% in cracking load, yield load, peak load, and ultimate load, respectively. Flexural stiffness increases by 56.4%, the ductility coefficient improves by 26.2%, and the average crack spacing reduces by 28.5% . (2) Reinforcement ratio is identified as a primary influencing factor. As the reinforcement ratio increases from 0.28% to 1.27%, the yield load, peak load, and ultimate load increase dramatically by 128.3%, 128.8%, and 177.1%, respectively, flexural stiffness improves by 67.6%, and average crack spacing decreases by 28.5% . The results confirm that the contribution of fibers to the tensile resistance cannot be neglected. Based on back-calculation from experimental data, a recommended equivalent coefficient of 0.40 for the tensile zone is proposed. Calculations using this value show good agreement with test results.

Translated title of the contributionExperimental Study on Flexural Performance of Steel/Polypropylene Hybrid Fiber-Reinforced Ultra-High Performance Concrete Beams
Original languageChinese (Traditional)
Pages (from-to)76-87
Number of pages12
JournalTunnel Construction
Volume45
DOIs
StatePublished - Dec 2025

Fingerprint

Dive into the research topics of 'Experimental Study on Flexural Performance of Steel/Polypropylene Hybrid Fiber-Reinforced Ultra-High Performance Concrete Beams'. Together they form a unique fingerprint.