Abstract
Since the double-skin steel plate concrete composite wall can be used as the lateral force resisting member,there are some advantages,such as high capacity,excellent energy dissipation and favorable ductility. Double-skin steel plate concrete composite walls in high-rise buildings are subjected to vertical loading,but the elastic buckling of steel plate is not allowed. Although the initial geometrical imperfection of steel plate is a critical influencing factor for the buckling stress,it was not considered in the calculation of the buckling stress. The finite element model(FEM)of double-skin composite walls was established by using ABAQUS in consideration of initial geometric imperfection of steel plate. The buckling strain of steel plate,load-displacement curves and failure modes obtained by FEM matched well with those from the test. The parametric analysis was conducted to study the influence of initial geometric imperfection,welding spot spacing-to-thickness ratio and steel yielding stress. The equation of steel plate buckling stress accounting for initial geometric imperfections was proposed.
| Translated title of the contribution | Buckling Behavior of Steel Plate in Composite Shear Walls with Double-Skin Steel Plate and Filled Concrete Under Compression |
|---|---|
| Original language | Chinese (Traditional) |
| Pages (from-to) | 37-45 |
| Number of pages | 9 |
| Journal | Progress in Steel Building Structures |
| Volume | 26 |
| Issue number | 4 |
| DOIs | |
| State | Published - Apr 2024 |
| Externally published | Yes |
Fingerprint
Dive into the research topics of 'Buckling Behavior of Steel Plate in Composite Shear Walls with Double-Skin Steel Plate and Filled Concrete Under Compression'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver