Skip to main navigation Skip to search Skip to main content

新型连梁剪力墙结构拟静力试验研究

Translated title of the contribution: Quasi-static test study of coupled shear walls with a new type of coupling beams
  • Guo Shan Xu*
  • , Xing Tong
  • , Xi Zhan Ning
  • , Bin Wu
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Two full-scale single-story coupled shear wall specimens were designed, one with traditional reinforced concrete coupling beams and the other with improved triangular steel plate dampers. The yield failure modes and seismic performance of the two specimens were studied by quasi-static tests. The results show that the energy dissipation and deformation capacity of the new type of coupling beams were obviously larger than those of the traditional coupling beams. The stiffness and strength degradations were less than those of the traditional coupling beams. The deformation and energy dissipation of the new type of coupling beams were concentrated in the dampers. The concrete coupling beams were generally in good condition. The dampers can control structural damage well, which is conducive to the replacement of the coupling beams after earthquakes.

Translated title of the contributionQuasi-static test study of coupled shear walls with a new type of coupling beams
Original languageChinese (Traditional)
Pages (from-to)188-197
Number of pages10
JournalGongcheng Lixue/Engineering Mechanics
Volume36
Issue number12
DOIs
StatePublished - 1 Dec 2019

Fingerprint

Dive into the research topics of 'Quasi-static test study of coupled shear walls with a new type of coupling beams'. Together they form a unique fingerprint.

Cite this